sensing distance: 22 mm | current rating: 0,5 A @ 30 V DC | flush mount | NO (short circuit when door is open)
sensing distance: 22 mm | current rating: 0,5 A @ 30 V DC | flush mount | NO (short circuit when door is open)
micro switch | sensing distance: 3 mm | current rating: 0,5 A @ 100 V DC | flush mount | NC (short circuit when door is closed)
sensing distance: 25 mm | current rating: 0,5 A @ 100 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 78 mm | current rating: 0,5 A @ 100 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 55 mm | current rating: 0,5 A @ 100 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 55 mm | current rating: 0,5 A @ 100 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 50 mm | current rating: 0,2 A @ 15 V DC | surface mount | NC (short circuit when door is closed)
Material: stainless steel | Inner diameter: 9.4 mm | Length: 410 mm | Mounting: surface mount
Material: stainless steel | Inner diameter: 9.4 mm | Length: 410 mm | Mounting: surface mount
Material: stainless steel | Inner diameter: 10,5 mm | Length: 410 mm | Mounting: surface mount
Material: stainless steel | Inner diameter: 16 mm | Length: 410 mm | Mounting: surface mount
Material: stainless with plastic coating | Inner diameter: 6 mm | Length: 300 mm | Mounting: surface mount
Material: stainless with plastic coating | Inner diameter: 6 mm | Length: 300 mm | Mounting: surface mount
Material: stainless with plastic coating | Inner diameter: 6 mm | Length: 300 mm | Mounting: surface mount
Material: stainless with plastic coating | Inner diameter: 6 mm | Length: by the linear meter
Material: stainless steel with plastic coating | Inner diameter: 6 mm | Available in meters | Antracit
Material: stainless with plastic coating | Inner diameter: 6 mm | Length: by the linear meter
Material: stainless steel with plastic coating | Inner diameter: 6 mm | Available in meters | Brown
Material: stainless with plastic coating | Inner diameter: 6 mm | Length: by the linear meter
Material: stainless steel with plastic coating | Inner diameter: 6 mm | Available in meters | White | 100 meters.
Material: plastic | Mounting: surface mount | Compatible with: DLK-403D|G | Anthracite
Material: plastic | Mounting: surface mount | Compatible product: DLK-403D|G | Antracit
Material: plastic | Mounting: surface mount | Compatible with: DLK-403D|G | Brown
Material: plastic | Mounting: surface mount | Compatible with: DLK-403D|G | White
Material: plastic | Mounting: surface mount | Compatible product: DLK-403D|G | White
ABS plastic | 3 contacts | 2 A @ 36 V DC | flush mountable into hinge side
ABS plastic | 2 contacts | 5 A @ 36 V DC | flush-mountable into lock side
ABS plastic | 2 contacts | 5 A @ 36 V DC | flush-mountable into lock side
ABS plastic | 3 contacts | 3 A @ 36 V DC | flush mountable into hinge side
ABS plastic | 5 contacts | 3 A @ 36 V DC | flush mountable into hinge side
ABS plastic | 2 contacts | 2 A @ 30 V DC | flush mountable into hinge side
Function: Battery holder bracket | Mounting: DIN rail | Compatibility: AKKU-12-7-RITAR
Mounting box | Outdoor/indoor | Lockable with key | Powder-coated metal | IP65 | Equipped with mounting grid and DIN rail.
LED indicator | Flush mounted | Drilling diameter: 16 mm | Color: red-green | IP65
LED indicator | Flush mounted | Drilling diameter: 19 mm | Color: red-green | IP65
Impulse | 2 channel | Relay load capacity: 10 A@250 V AC | Output voltage: 12 V AC | Wiring: soldered | NO/NC
Impulse | 4 channel | Relay load capacity: 5 A@250 V AC | Output voltage: 12 V AC | Wiring: soldered | NO/NC
Impulse | 4 channels | Relay load capacity: 5 A@240 V AC; 5 A@28 V DC | Output voltage : 12 V DC | Wiring: soldered | NO/NC
2 channels | Wiring: terminal blocks | DIN rail compatible | Material: plastic | Dimensons: 68×22×29 mm
4 channel | Wiring: terminal block | DIN rail compatible | Material: plastic | Dimensons: 68×29×29 mm
Function: Lock control | Fail-safe (NC) locks | Wiring: terminal block | Dimensons: 69×60×15 mm
Timing: 0-30s | Output: NO/NC | Power supply: 12 V DC | Output max. load: 10A @ 12 V DC
1 channel | Power supply: 12 V DC | Output max. load: 10 A@120 V AC | Wiring: terminal block | NO/NC
1 channel | Power supply: 12/24 V DC | Output max. load: 10/6 A@125 V AC/24 V DC | NO/NC
1 channel |Power supply: 12/24 V DC | Output max. load: 7A @230V | NO/NC
2 channels | Power supply: 12 V DC | Output max load: 1A@125V AC, 2A@30V DC | NO/NC
Material: Stainless steel | Finish: polished | Mounting: Surface mount | Compatible with: SD-50-M2 conduit
Material: stainless with plastic coating | Inner diameter: 6 mm | Length: 300 mm | Mounting: surface mount
Material: chrome-plated steel | Recessed mounting | Inner diameter: 9 mm | Length: 290 mm
Material: stainless steel | Recessed mounting | Inner diameter: 9 mm | Length: 290 mm
Material: chrome-plated steel | Recessed mounting | Inner diameter: 9 mm | Length: 540 mm
Function: Timing and Delay | Relay: Yes | Display: 7-segment | Timing and Delay Range: 0.1 seconds - 999 minutes | Modes: 9 different modes
Function: timing and delay | Relay: Yes | Display: 7-segment | Timing and delay range: 0,01 seconds - 999 minutes | Programs: 32
sensing distance: 14 mm | current rating: 0,5 A @ 30 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 14 mm | current rating: 0,5 A @ 30 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 14 mm | current rating: 0,5 A @ 30 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 19 mm | current rating: 0,5 A @ 30 V DC | surface mount | NO/NC
sensing distance: 16 mm | current rating: 0,5 A @ 30 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 16 mm | current rating: 0,5 A @ 30 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 12 mm | current rating: 0,5 A @ 30 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 12 mm | current rating: 0,5 A @ 30 V DC | surface mount | NC (short circuit when door is closed)
sensing distance: 18 mm | current rating: 0,5 A @ 30 V DC | flush mount | NC (short circuit when door is closed)
sensing distance: 18 mm | current rating: 0,5 A @ 30 V DC | flush mount | NC (short circuit when door is closed)
sensing distance: 15 mm | current rating: 0,5 A @ 30 V DC | flush mount | NC (short circuit when door is closed)
sensing distance: 15 mm | current rating: 0,5 A @ 30 V DC | flush mount | NC (short circuit when door is closed)
sensing distance: 15 mm | current rating: 0,5 A @ 30 V DC | flush mount | NC (short circuit when door is closed)
sensing distance: 18 mm | current rating: 0,5 A @ 30 V DC | flush mount | NC (short circuit when door is closed)
sensing distance: 29 mm | current rating: 0,5 A @ 30 V DC | flush mount | NC (short circuit when door is closed)
sensing distance: 29 mm | current rating: 0,5 A @ 30 V DC | flush mount | NC (short circuit when door is closed)
sensing distance:50 mm | current rating: 0,5 A @ 30 V DC | surface mount | NC (short circuit when door is closed)